ME2400 Vortex Flow Meter

ME2400 Vortex Flow Meter

Introduction

ME2400 Vortex Flowmeter works on the Karman vortex street principle that swirls generated by a bluff body in the pipe. The number of swirls are proportional to the volumetric flow in the pipe. Vortex flowmeter widely used for gases, steam and liquid applications. It is ideal for measuring saturated and superheated steam in large facilities to improve steam production efficiency.

Principle

When the fluid in the pipeline passes the bluff body (triangular prism), vortices will be generated due to the acceleration of partial flow rate. The vortices will arise alternatively in two lines, which is called Karman vortex. The releasing frequency of Karman vortex depends on the size of triangle prim and flow rate of fluid, while independent of the medium feature parameter, such as the temperature, pressure, it can be indicated by the following

formulas:

F=sR*v (1-1.27*d/D) | Q=3600*F/K | M=Q*P

Features

  • Integrated pressure and temperature compensation 0 4-20mA, pulse with HART or pulse with RS485 are selectable

  • Wide temperature range up to highest temperature 350°C

  • Embedded sensor, 4 piezo-electric crystal encapsulated inside the sensor.

  • No moving parts, no abrasion, non-wearing parts inside, fully welded SS304 body (SS316 selectable)

Specifications:

Line Size : 15 ~ 400 mm
Accuracy : ±1% FS
Output : Pulse/ 4-20mADC Analog
Power Input : 24 VDC (±10%); Remote version with 3.4V Lithium Battery
Operating Pressure : Standard 1.6 MPa; Custom 2.5 -4.0MPa
Operating Temperature : (-)10°C ~ 350°C
Sensor & Body Material : SS321/SS304/SS316
Ambient Temperature : (-)30°C ~ 60°C

Key Applications:

  • Liquefied Gases
  • Flue Gases
  • Fully Demineralized Water
  • Nitrogen
  • Solvents
  • Carbon Dioxide
  • Condensate
  • Heat-Transfer Oils
  • Boiler Feedwater
  • DM water